Articulate Probe With Flat and Cone Shaped Hand (10.5~11.5 year old)
1. The probes were designed with a center pin to rotate the hand with respect to the lower arm,
that motion can be equivalently represented by rotating the probe.
2. The finger “tip” is developed to match the dimensions of the UL articulated probe, the diameter
from the tip to the first joint then tapers from the tip dimensions to the finger diameter. The joints
are spaced equally along the finger length.
3.The probe is designed to permit the hand to “bend” with respect to the arm using a hinge pin located
6mm(0.24in) from the hand length(wrist end) and the hand is restricted in bending not more than 90 °
with respect to the arm.
If the upper arm is required to evaluate a part it shall consist of a flexible tube attached at the end of the
lower arm, as the exact position of the elbow cannot be readily determined from the date points chosen.
Reference Standard: UL 60335-2-24 Figure 101.DVA.2.