Home > Products > Material Flame Test Machine > UL94 Test Flames 50W/500W Horizontal and Vertical Flame Test

UL94 Test Flames 50W/500W Horizontal and Vertical Flame Test

Description:It simulates electronic products around the environment in the early condition, using the simulation technology to assess the fire risk. The test equipment apply to the electrical and electronic product components of household appliances, spare parts

  • Model:AUTO-SPA
  • Manufacturer:
  • Update time:2024-01-16
  • Visits:39
Product details


1.Overview:

When there is a fire around the products, should ensure that it will not to cause the spread of
the fire, horizontal-vertical burning test simulates electronic products around the environment
in the early condition, using the simulation technology to assess the fire risk. The test equipment
apply to the electrical and electronic product components of household appliances, spare parts
and components, such as: household appliances insulation shell, Panel switches, printed circuit
boards and insulation materials and so on.
 
2.Characteristics:

Horizontal-vertical flame chamber tester is composed by the test part and control part, using the
integrated design, to facilitate the installation at the scene and debug.The shell of the test chamber
and the important parts are all manufactured by stainless steel, resistant cigarettes and gas corrosion.
The automatic degree of control system is high. Has automatic ignition, the products which were tested
in both vertical and horizontal orientation has the function automatically follow flame in the cross of the
test. Time and temperature figures show, so that the observation and records is facilitate and the use
of it is stable and reliable.


ModelAUTO-SPAAUTO-SPA
Kinds500W(5V class)50W(HB/V class)
Test flame500W(burning test for V-0,V-1,V-2 classification)50W(burning test for V-0,V-1,V-2 classification)
Burner TubeInternal diameter: Φ 9.5mm±0.3mmInternal diameter: Φ 9.5mm±0.3mm
Burning Angle0°,20°,45°0°,20°,45°
ThermocoupleType K (Ni/Cr - Ni/Al)Type K (Ni/Cr - Ni/Al)
Thermocouple Size 0.5 mm0.5 mm
Copper BlockΦ9mm±0.01mm,weight:10g±0.05g before drilling. Φ5.5mm±0.01mm, weight:76g±0.01g before drilling. 
Time for Temperature to IncreaseFrom 100°C±5°C to 700°C±3°C; 54s±2s (preset)From 100°C±5°C to 700°C±3°C;44s±2s (preset)
Gas Flow965±32ml/min105±10ml/min
Gas Supplymethane,min.98% puritymethane,min.98% purity
water-column 125m±5mm‹10mm
Test Time54±2s44±2s
Flame Height Indicator40±1mm20±1mm
Volume Of Chamber>0.5m³, black interior>0.5m³, black interior
Conform to standardUL94,IEC60695-11-3,IEC60695-11-20UL94,IEC60695-11-3,IEC60695-11-20
Power SupplyAC220V±10%/50HzAC220V±10%/50Hz
Display panel languageAll EnglishAll English




Reference Standards:IEC60695-11-20.IEC60695-11-3,UL94.